EAS3000 Manually Operated Check Valve

•Modular Design, could combine with EA3000 series by using the bracket. 

•This valve can be used as a manual 3/2 ways check valve 

•Switching position (EXH./SUP.) is immediately recognizable 

•Standards for operator installation: when repairing and maintaining machinery, Residual    pressure relief 

  valve can be used to eliminate residual pressure 

  while closing the air source.In this case, unintentional manipulation by a third 

  party can cause a sudden movement of the rear line pressure, cylinders, etc., 

  which can lead to injury. Therefore, the provisions: all used for this purpose 

  must be locked, to prevent the third party unintentional operation resulting in damage      to the operator; 

•In addition to the standard type, a pressure gauge type is available (square or round ), If    needs, please 

  contact E.MC for customization 

Configure your product

Back
How to Order?

Order Example: 

EAS3000 manually operated check valve, 1/4” port size, with bracket, G thread ERP code is EAS3000-02 

 

Specifications
Model EAS2000-01 EAS2000-02 EAS3000-02 EAS3000-03 EAS3000-04 EAS4000-03 EAS4000-04 EAS4000-06
Working medium Clean air (after 40um filtration)
Port Size 1/8 1/4 1/4 3/8 1/2 3/8 1/2 3/4
EXH. port size 1/4 3/8 1/2
Guaranteed pressure(MPa) 1.5
Working Pressure Range(MPa) 0~0.9
Acting type Manual
Positions 3/2 Ways
Working Temperature(℃) -5~60(No freezing)
Weight(g) 144 141 284 277 270 669 659 639
Internal Structure

Main Dimension